24 XR20 User’s Guide User Menu
System Test
User Code Level: Master or Standard.
Function: System Test is used to test the battery, alarm bell
or siren, and central station communi cation. The System Test
function begins automatically as soon as you select it.
Using the System Test Function
1. Access the User Menu.
2. Press the COMMAND key until SYSTEM TEST? displays.
3. Press any Select key. The system test begins automatically
and the keypad displays:
1) BELL SOUNDING during a two second bell test, then:
2) BATTERY - OKAY or BATTERY - TRBL to indicate the
battery condition, then:
3) TRANSMIT TEST * and ATTEMPT NO : 1 during the
transmit test, then:
4) TRANSMIT OKAY or TRANSMIT FAILED to show the
transmit test results, then:
5) TEST END to indicate the System Test is complete.
6) Press the Back Arrow key to end the system test.
* The transmit test does not occur on local systems.
Testing your system burglary protection: The System Test function
should be part of your weekly testing and should be followed by
placing the burglary devices in Zone Monitor mode. This allows
you to open and then close each protected door and window while
listeningforthekeypadtobeepconrmingitsoperation.SeeZone
Monitor.
Using the Zone Monitor Function
1. Access the User Menu.
2. Press the COMMAND key until ZONE MONITOR? displays.
3. Press any Select key.
The keypad displays PERIM ALL NBR.
4. Select PERIM to place all disarmed perimeter zones into
Zone Monitor.
4a. The keypad displays PERIM? ADD RMV.
4b. Select ADD to add all perimeter zones to Zone Monitor.
4c. Select RMV to remove all perimeter zones.
5. Select ALL to place all disarmed zones into Zone Monitor.
5a. The keypad displays ALL? ADD RMV.
5b. Select ADD to add all disarmed zones to Zone Monitor.
5c. Select RMV to remove all disarmed zones.
6. Select NBR to enter a specic zone number for zone
monitor.
7. If NBR is selected, the keypad displays ZONE : - ADD RMV.
7a. Enter any zone number and select ADD to add this
zone.
7b. Enter any zone number and select RMV to remove the
zone.
8. The zone number automatically disappears and a new zone
number can then be entered. See step 7.