Digital Monitoring Products 7000 Series Keypad Installation Guide
10
7000 Series Keypad Installation Guide Digital Monitoring Products
11
Keypad Entry Delay
All Systems
Once the entry delay starts, the keypad sounds an entry tone and displays ENTER CODE: - . Present your card to
the reader. Once validated, the system disarms all areas accessible by you and activates the 7073 Door Strike relay.
Area systems provide a delay to allow selected areas only to be disarmed. See Keypad Arming and Disarming.
Entry delay starts.
The System disarms the area and activates the Door Strike Relay.
ABC SECURITY
ENTER CODE: –
Figure 12: Entry Delay
Keypad Specications
MODEL
NORM/STANDBY
CURRENT
ALARM
CURRENT
4-ZONES
INTERNAL
PROX READER
WIEGAND
INPUT
INTERNAL FORM C
DOOR STRIKE RELAY
7060 72mA 87mA
7063 85mA 100mA X
7070
72mA + 1.6mA
per active zone
87mA + 2mA
per active zone
X
7073
85mA + 1.6mA
per active zone
100mA + 2mA
per active zone
X X X X
Wiring Specications
When planning a keypad bus installation, keep in mind the following specications:
1. DMP recommends using 18 or 22-gauge unshielded wire for all keypad and LX-Bus circuits. Do Not use
twisted pair or shielded wire for LX-Bus and keypad bus data circuits. To maintain auxiliary power integrity
when using 22-gauge wire do not exceed 500 feet. When using 18-gauge wire do not exceed 1,000 feet.
Install an additional power supply to increase the wire length or add devices.
2. Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge. This
distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than
2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases.
3. Maximum number of devices per 2,500 feet circuit is 40. On XR500 Series and XR2500F panels, the maximum
number of LX-Bus devices per 2,500 feed circuit is 25.
Note: Each panel allows a specic number of supervised keypads. Add additional keypads in the
unsupervised mode. Refer to the panel installation guide for the specic number of supervised keypads
allowed.
4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0 VDC. If the
voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit.
When voltage is too low, the devices cannot operate properly.
Refer to the LX-Bus/Keypad Bus Wiring Application Note (LT-2031) for more information. Also see the 710/710F
Module Installation Sheet (LT-0310).