INSTALLATION GUIDE
7000 Series Thinline™ LCD Keypads
Models 7060/7063/7070/7073
Description
The DMP Model 7060, 7063, 7070, and 7073 Thinline™ LCD Keypads offer the same exible features and functionality
as current DMP keypads in a stylish, sleek new design. Each keypad provides four 2-button Panic keys, AC power
LED, Armed LED, 32-character display, backlit logo and keyboard with easy-to-read lettering and an internal speaker.
In addition, the Models 7070 and 7073 keypads also provide four fully programmable Class B, Style A protection zones
you can program for a variety of burglary and access control applications.
The Model 7063 and 7073 keypads provide a built-in proximity card reader designed to read HID 1300 Series
proximity credentials. The Model 7073 keypad also provides a door strike relay and allows Wiegand input from HID,
DMP, or other external card readers.
Installing the Keypad
The keypad housing is designed to easily install on any 4” square box, 3-gang switch box, DMP 695 and 696 backbox,
or a at surface. Figure 1 shows the keypad housing mounting hole locations.
Removing the Base
The keypad housing is made up of two parts: the front, which contains the circuit board,
keyboard components, and the base. To remove the base, insert a at screwdriver into one
of the openings on the bottom and twist the screwdriver while pulling the halves apart.
Repeat with the other opening.
Harness Wiring
Figure 1 shows wiring harness assignments. Observe wire colors when connecting the
red, yellow, green, and black wires to the keypad bus. When wiring directly to the panel
terminals, connect red to panel terminal 7, yellow to terminal 8, green to 9, and black to
panel terminal 10. Use 1k Ohm EOL resistors, DMP Model 311, on keypad zones 1 through 4.
The 7060 and 7063 keypads are supplied with a 4-wire harness for panel keypad bus connection.
The 7070 and 7073 keypads are supplied with a 12-wire data bus/zone harness. Four wires connect to the keypad
bus. The remaining eight wires are for the four zone inputs: two wires for each zone.
The 7073 keypad is also supplied with one 5-wire output/reader harness.
Surface and Backbox
Mounting Holes
Combined 4-square
and 3-gang switch box
Mounting Holes
Keypad Back
Surface and Backbox
Mounting Holes
1K EOL
1K EOL
1K EOL
1K EOL
Green/White – Connect Reader Data 0
White – Connect Reader Data 1
Orange – Door Strike Normally Open
Gray – Door Strike Common
Violet
– Door Strike Normally Closed
Yellow/Whit
e
White/Yello
w
Orange White
White/Orange
Red/White
White/Re
d
Brown/White
White/Brow
n
Black – Ground
Green – Receive Data
Yellow – Send Data
Red – Keypad Power
– Zone
4
– Zone
3
– Zone
2
– Zone 1
External Reader/
Door Strike
7073 Keypad
Zones 1 through 4
7070 and 7073
Keypads
All Keypads
Figure 1: Keypad Back Showing Wiring Harness Assignments
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Models 7060/7063/7070/7073

INSTALLATION GUIDE7000 Series Thinline™ LCD KeypadsModels 7060/7063/7070/7073DescriptionThe DMP Model 7060, 7063, 7070, and 7073 Thinline™ LCD Keypads

Page 2 - Card Readers

Digital Monitoring Products 7000 Series Keypad Installation Guide107000 Series Keypad Installation Guide Digital Monitoring Products117063 and 7073

Page 3 - 

Digital Monitoring Products 7000 Series Keypad Installation Guide107000 Series Keypad Installation Guide Digital Monitoring Products11Keypad Entry D

Page 4 - Entering Alpha Characters

LT-0778 (8/05) © 2005 Digital Monitoring Products, Inc.800-641-4282www.dmp.comMade in the USAINTRUSION • FIRE • ACCESS • NETWORKS2500 North Partnershi

Page 5 - Installer Options Menu

Digital Monitoring Products 7000 Series Keypad Installation Guide27000 Series Keypad Installation Guide Digital Monitoring Products3Additional Power

Page 6

Digital Monitoring Products 7000 Series Keypad Installation Guide27000 Series Keypad Installation Guide Digital Monitoring Products37073 Door Strike

Page 7

Digital Monitoring Products 7000 Series Keypad Installation Guide47000 Series Keypad Installation Guide Digital Monitoring Products5End-User Options

Page 8

Digital Monitoring Products 7000 Series Keypad Installation Guide47000 Series Keypad Installation Guide Digital Monitoring Products5Installer Option

Page 9

Digital Monitoring Products 7000 Series Keypad Installation Guide67000 Series Keypad Installation Guide Digital Monitoring Products7ZONE 2 SOFTSHUNT

Page 10 - Keypad Door Strike

Digital Monitoring Products 7000 Series Keypad Installation Guide67000 Series Keypad Installation Guide Digital Monitoring Products7WIEGAND CODE LEN

Page 11 - Wiring Specications

Digital Monitoring Products 7000 Series Keypad Installation Guide87000 Series Keypad Installation Guide Digital Monitoring Products9NO OF USER CODE

Page 12 - Compatibility

Digital Monitoring Products 7000 Series Keypad Installation Guide87000 Series Keypad Installation Guide Digital Monitoring Products9Accessing Keypad

Comments to this Manuals

No comments