Digital Monitoring Products 714-715 Installation Guide
2
Keypad Bus Addressing
The ONES rotary switch must be set to a starting address that communicates the status of the rst four zones (Z1 through
Z4) on the expansion module. The next consecutive keypad address is automatically used to communicate the status of
the next four zones (Z5 through Z8), etc.
For example, when you set the TENS switch to 0 and the ONES switch to 2, the rst four expander zones respond as
zones 21 through 24. Expander zones 5 through 8 respond as panel zones 31 through 34; zones 9 through 12 respond
as panel zones 41 through 44; and zones 13 through 16 respond as panel zones 51 through 54. Refer to Tables 1 and 2
for keypad bus zone numbers and the panels where they operate.
Start Address
Expander Zones
1-4 5-8 9-12 13-16
Switches
Tens Ones
XR500 or XR350/XR550 Series Panel Zones
0 1 11 to 14 21 to 24 31 to 34 41 to 44
0 2 21 to 24 31 to 34 41 to 44 51 to 54
0 3 31 to 34 41 to 44 51 to 54 61 to 64
0 4 41 to 44 51 to 54 61 to 64 71 to 74
0 5 51 to 54 61 to 64 71 to 74 81 to 84
0 6 61 to 64 71 to 74 81 to 84 91 to 94
0 7 71 to 74 81 to 84 91 to 94 101 to 104
0 8 81 to 84 91 to 94 101 to 104 111 to 114
0 9 91 to 94 101 to 104 111 to 114 121 to 124
1 0 101 to 104 111 to 114 121 to 124 131 to 134
1 1 111 to 114 121 to 124 131 to 134 141 to 144
1 2 121 to 124 131 to 134 141 to 144 151 to 154
1 3 131 to 134 141 to 144 151 to 154 161 to 164
1 4 141 to 144 151 to 154 161 to 164 None
1 5 151 to 154 161 to 164 None None
1 6 161 to 164 None None None
Table 1: Keypad Bus Zone Numbers
Start Address
Expander Zones
1-4 5-8 9-12 13-16
Switches
Tens Ones
Panel Zones
XT30, XT50, XR100 or XR150
0 1 11 to 14 21 to 24 31 to 34 41 to 44
0 2 21 to 24 31 to 34 41 to 44 51 to 54
0 3 31 to 34 41 to 44 51 to 54 61 to 64
0 4 41 to 44 51 to 54 61 to 64 71 to 74
0 5 51 to 54 61 to 64 71 to 74 81 to 84
0 6 61 to 64 71 to 74 81 to 84 None
0 7 71 to 74 81 to 84 None None
0 8 81 to 84 None None None
Table 2: Keypad Bus Zone Numbers